CAT6 Cabling Installation Guide for Fast and Reliable Networks

A fast network rarely fails because of the switch on the rack or the access point on the ceiling. More often, the weak point is hidden in the walls, above the tiles, or bundled carelessly in a crowded closet. I have seen offices spend heavily on new firewalls, managed switches, and faster internet circuits, only to discover that their performance bottleneck was poor network cabling installed years earlier with no real plan. That is why CAT6 cabling still matters. It sits in a practical sweet spot for many commercial environments, offering solid bandwidth, dependable performance, and reasonable installation cost. When the work is done well, users never think about it. Video calls stay stable, file transfers move quickly, printers behave, VoIP phones stop dropping, and the network team gets fewer mysterious tickets. A proper CAT6 cabling installation is not just about pulling cable from point A to point B. It is a low voltage cabling project that affects reliability, future upgrades, troubleshooting time, and even the look and usability of the space. Good installers think about bend radius, cable pathways, labeling, patch panel layout, certification, and what the business will need three years from now, not only what it needs this week. What CAT6 is really meant to do CAT6 cabling was designed to support Gigabit Ethernet comfortably and, under the right distances and conditions, can also support 10 Gigabit Ethernet over shorter runs. In many offices, that is more than enough. A typical workstation does not need 10 gigabit to the desk. Most users need consistent, low-latency access to cloud platforms, internal files, voice services, and wireless infrastructure. CAT6 handles that well when the installation is clean. It helps to separate cable category marketing from practical business network installation. People often hear CAT6, CAT6A, and fiber discussed together and assume newer always means better. That is not always true. Better means appropriate for the site, the distance, the environment, the budget, and the growth plan. For a small or mid-sized office, CAT6 often makes excellent sense for office network cabling to desks, conference rooms, printers, cameras, and many wireless access points. CAT6A cabling becomes more attractive when the design calls for widespread 10 gigabit links over full channel lengths, higher power PoE devices, or denser bundles where alien crosstalk and heat deserve extra attention. CAT6A is thicker, stiffer, and usually more labor-intensive to terminate and route. Those trade-offs matter in real ceilings and tight risers. Start with the building, not the cable box Every solid network cabling installation begins with a walk-through. Before anyone unspools a reel, someone needs to understand the building. That means ceiling type, wall construction, riser access, existing conduits, electrical pathways, telecom room location, HVAC conditions, and the likely path between users and the main distribution point. Older buildings are where assumptions go to die. You may expect an easy route above a drop ceiling, then find fire breaks, crowded conduit, or legacy cabling abandoned in place. Newer spaces have their own issues, especially open offices with polished concrete, exposed ceilings, or furniture layouts that may change every quarter. In those environments, floor boxes, columns, consolidation points, and neatly planned structured cabling matter more than people realize during design. A few questions early in the project can prevent expensive change orders later: How many active drops are needed now, and how many are likely within the next two to three years? Which endpoints need PoE, such as phones, cameras, access points, or access control devices? Where will switches, patch panels, and rack equipment live, and is there adequate power and cooling? Are any cable routes going through plenum spaces, outdoors, or between buildings? Will any runs realistically need CAT6A cabling or fiber instead of standard CAT6? Those questions shape nearly everything that follows. They also separate a thoughtful data cabling project from a hurried pull-and-terminate job. Planning the cable plant for real use The easiest network to support is the one that was laid out logically. That sounds obvious, yet many offices end up with patchwork cabling because each expansion was handled as an isolated task. A new conference room gets three drops, then a copier moves, then a security camera appears near the rear exit, then another tenant vacates a suite and the floor plan changes. Without a plan, the rack becomes a puzzle and the ceiling becomes a tangle. A proper structured cabling design should map user locations, shared devices, wireless coverage, and support spaces. For desks, I usually recommend at least two data ports per station in business environments that expect stability and flexibility, even if only one is activated at move-in. That extra port often saves a lot of trouble later when a phone, docking station, printer, or second device appears. Conference rooms usually need more than people first estimate. A room that currently supports a display and a conference phone may soon need a room PC, a wireless presentation unit, a camera, and a dedicated access point. Telecom rooms deserve just as much attention as work areas. The rack layout should leave space for clean patching, horizontal and vertical cable management, labeled patch panels, UPS hardware, and switch growth. I have seen technically functional closets become operational hazards because no one left room for service loops, airflow, or future panels. That kind of shortcut rarely shows up in the initial quote, but it costs time every time someone has to trace a port. Choosing CAT6, CAT6A, or something else Most people asking for CAT6 cabling are actually asking for confidence. They want to know the network will hold up for years. The answer depends on use case. CAT6 works well for the majority of horizontal runs in standard office settings. It is easier to install than CAT6A, easier to manage in bundles, and less physically demanding in crowded pathways. If the goal is dependable Gigabit Ethernet to endpoints, strong PoE support, and headroom for normal business traffic, CAT6 is still a sensible choice. CAT6A cabling earns its keep in situations where full 10 gigabit support over longer distances is part of the design target, or where power and cable density are significantly higher. Large conference suites, media-heavy teams, certain industrial spaces, and high-end commercial builds sometimes justify that investment. The labor side matters, though. CAT6A has a larger diameter and tighter handling requirements. Installers need more room in pathways, larger fill calculations, and more patience at the patch panel. There is also the issue of future proofing, a phrase that gets overused. Installing CAT6A everywhere because it might be useful someday is not always prudent. Sometimes the smarter path is CAT6 for horizontal ethernet cabling, plus fiber uplinks between telecom rooms, floors, or buildings. That combination often gives businesses the performance they need without overcomplicating every endpoint run. The installation work that determines performance Cable category alone does not guarantee results. I have tested brand-new cable that failed certification because it was pulled too hard, kinked around sharp framing, dressed too tightly with zip ties, or untwisted too far back at termination. Good data cabling lives or dies on workmanship. Pull tension matters. So does bend radius. Copper cable is more forgiving than people think until it suddenly is not. A cable can look fine from the outside while its internal geometry has been compromised. Once that happens, the link may pass a basic continuity check but struggle under actual network load, especially on higher-speed links or when PoE is involved. Separation from electrical lines is https://cablelines035.theburnward.com/ethernet-cabling-tips-for-faster-troubleshooting-and-less-downtime another common problem. In commercial environments, low voltage cabling often shares routes with other services, but it still needs proper spacing and support. That becomes especially important near fluorescent lighting systems, motors, elevator equipment, and electrical feeders. The exact separation requirements depend on local code, the type of pathway, and shielding choices, so the installer must know both standards and site conditions. Termination quality also matters more than many clients expect. Keystones, jacks, patch panels, and patch cords are part of the channel. Mixing poor-quality components into an otherwise decent CAT6 cabling job is a false economy. It usually shows up later as intermittent link drops or unexplained speed negotiation issues. For that reason, experienced installers pay attention to a handful of discipline points during the work: Keep cable twists intact as close to the termination point as practical. Maintain bend radius and avoid tight cinching that deforms the jacket. Support cables properly in trays, hooks, or approved pathways, not on ceiling grids. Label both ends clearly and consistently before the project starts growing. Test and certify every installed run, not just a sample. Those habits are not glamorous, but they are what make a network stable. Pathways, fire code, and building realities One of the biggest differences between DIY cabling and professional network cabling installation is respect for the building itself. A cable route is never just a route. It may involve plenum spaces, fire-rated walls, shared risers, asbestos concerns in older sites, occupancy restrictions, and coordination with electricians, HVAC crews, or general contractors. Cable jacket type is a good example. Plenum-rated cable is required in certain air-handling spaces, while riser-rated cable may be suitable in vertical shafts that are not used for air return. Using the wrong cable type can create code issues, inspection problems, and liability that far exceed the cost difference in materials. Fire stopping is another area where shortcuts cause headaches. Every penetration through a rated wall or floor needs proper treatment. I have walked into otherwise decent cabling projects where the data work looked clean but the penetrations were left open or patched casually. That puts the building owner and contractor in a bad position during inspection and can delay occupancy. The pathway itself should also reflect how the space will evolve. J-hooks may be fine in some areas. Tray may be better in denser routes or where future additions are expected. Conduit has value for exposed sections, vulnerable locations, and outdoor transitions, but it also has fill limits and can become a choke point if undersized. There is no single correct method for every building. Good judgment comes from balancing code, access, cost, and future maintenance. Rack layout and patching discipline A clean rack is not about aesthetics alone. It directly affects supportability. In a busy office, every unlabeled patch cord becomes a future service ticket. Every overstuffed patch panel makes adds and changes slower. Every unmanaged loop of cable blocks airflow and invites mistakes. For office network cabling, I prefer patch panels laid out in a way that mirrors floor geography whenever possible. One section for the north wing, one for conference rooms, one for support areas, one for wireless, and so on. This makes troubleshooting intuitive. Labels should be human-readable first, not just technically correct. A label like "IDF-A PP2 17" may satisfy internal logic, but "conf west table 1" is what helps during a live support call. Patch cords deserve some discipline too. This is one of the easiest places for a well-built structured cabling system to degrade over time. Cheap, overly long cords create clutter and strain. Random color use makes tracing harder. A simple color convention for voice, data, wireless, cameras, or uplinks can save real time, provided the team sticks with it. Testing is where good installers prove the work There is a major difference between proving a cable has continuity and proving it meets category performance. Continuity testers have their place, but they are not enough for professional business network installation. If a client is paying for CAT6 cabling, the installed links should be certified to the applicable standard using proper test equipment. Certification catches issues that visual inspection will miss. Return loss problems, excessive untwist, split pairs, near-end crosstalk, and marginal terminations can all hide until testing. On more than one project, I have seen a run look perfect on the faceplate and patch panel, only to fail because it was bent too sharply above a beam or damaged when another trade moved a lift through the space. The deliverable matters too. A proper test record gives the client a baseline. When a port acts up two years later, the team can compare current behavior against the original certified result. That is especially useful in multi-tenant offices, renovations, or sites where many contractors touch the ceiling over time. Common mistakes that cost more later The most expensive errors in network cabling are often the ones that seem minor during install. Leaving no slack at the rack sounds efficient until a panel needs retermination. Skipping labels saves an hour today and wastes ten later. Pulling cable through a cramped route without enough care may not show consequences until the day a department moves in and starts using every port at full load. Another frequent mistake is underestimating drop count. Businesses commonly outgrow their original assumptions faster than expected. A lobby gains digital signage. A break room gets a smart display. The IT team adds badge readers. The facilities group installs IP cameras. Suddenly the neat little switch stack is full and the original cable pathways are crowded. Running a few extra cables during the initial project is often far cheaper than reopening pathways later. There is also the temptation to mix cable categories and component grades haphazardly. A link is only as strong as the complete channel. If someone installs quality CAT6 horizontal cable but pairs it with bargain-bin jacks and old patch cords, they are not really buying a CAT6 system in practical terms. What a finished installation should leave behind A successful network cabling job should not end with the last faceplate screwed on. The client should receive something usable: labeled ports, test results, rack diagrams or at least logical port schedules, and clear identification of spare capacity. If there are exceptions, such as a run that took a nonstandard route or a temporary patch during construction, those details should be documented openly. This is where experienced contractors stand apart. They understand that data cabling is infrastructure, not just labor. Infrastructure needs records. The business may switch IT providers in the future. It may renovate, expand, or sublease part of the floor. Clear documentation keeps the cable plant valuable long after the original installers have left the site. When to bring in a specialist Not every cabling task needs a large contractor, but many business environments benefit from a team that handles low voltage cabling routinely. Multi-floor projects, healthcare spaces, warehouses, occupied offices, retail chains, and sites with access control or camera integration all introduce layers that can trip up a generalist. A specialist will usually spot issues earlier, from pathway congestion to patch panel sizing to code compliance around penetrations and cable type. They also tend to have better testing gear, better termination consistency, and stronger habits around documentation. That does not mean the lowest quote is always wrong or the highest quote is always right. It means the scope should be evaluated on workmanship standards, deliverables, testing, and long-term support, not just line-item material cost. The case for doing it once and doing it right CAT6 cabling is not flashy, but it is foundational. When planned carefully and installed with discipline, it gives businesses a dependable platform for everyday connectivity and future growth. Most of the value comes from choices that are invisible after the ceiling closes: proper routes, correct cable type, clean terminations, sensible rack design, and thorough certification. That is the real goal of network cabling installation. Not merely to pass traffic on day one, but to create a structured cabling system that remains organized, traceable, and reliable after furniture moves, staffing changes, and technology upgrades. If the office can add phones, access points, cameras, printers, and workstations without turning the telecom room into chaos, the cabling has done its job. For many environments, CAT6 remains the right answer. For some, CAT6A cabling or fiber belongs in parts of the design. The best result comes from matching the medium to the need, then executing the work with care. Fast and reliable networks are built that way, one clean run at a time.

Read more about CAT6 Cabling Installation Guide for Fast and Reliable Networks

Structured Cabling for Smart Offices: What Businesses Need to Know

A smart office is only as smart as the infrastructure behind the walls and above the ceiling. Businesses often focus on visible technology first, the video conferencing displays, access control readers, Wi-Fi access points, occupancy sensors, VoIP phones, and cloud applications. What makes those systems reliable is far less glamorous: structured cabling. When office technology works well, nobody talks about the cable plant. When it fails, everyone notices. Calls drop. Conference rooms freeze mid-meeting. Wireless coverage looks strong on paper but weak in practice. Security cameras pixelate at the worst time. The root cause is often not the app or the device. It is the network cabling design, the quality of the network cabling installation, or a mismatch between current needs and what was originally pulled into the space. Businesses planning a new office, a renovation, or a technology refresh need to treat structured cabling as long-term infrastructure, not a commodity purchase. That means understanding what it does, how it supports smart office systems, and where shortcuts usually come back to bite. Structured cabling is the office backbone Structured cabling is a standardized approach to connecting devices and systems across a building. Instead of ad hoc runs installed whenever a new need appears, you create an organized cabling framework with defined pathways, termination points, patch panels, racks, and labeling. The goal is simple: make the network predictable, scalable, and serviceable. In a modern office, that framework usually supports far more than desktop computers. It carries data for wireless access points, voice for IP telephony, power and connectivity for security cameras, links for door access systems, and often building controls as well. In https://www.networkcablingsalinas.net/sound-masking-system-installation-in-salinas-ca/ many projects, low voltage cabling now touches nearly every operational layer of the workspace. That broad scope is why office network cabling deserves strategic planning. A poor design can limit how many devices you can add later. It can also make troubleshooting miserable. I have seen offices where a single expansion over three years led to a patchwork of unlabeled cables, cheap switches mounted in odd corners, and ceiling spaces crowded with abandoned runs. It worked, more or less, until a floor-wide outage forced someone to trace connections by hand for half a day. A well-built system avoids that chaos. It gives you clear demarcation between provider handoff, core network gear, horizontal cabling, and endpoint devices. More importantly, it gives your business room to change without tearing the place apart every time a department moves desks or adds new hardware. Why smart offices put more pressure on the cable plant Ten years ago, many offices could get away with a fairly basic data cabling design. A few wall drops per workstation, some printer connections, a server closet, and enough Wi-Fi to cover common areas. Today the load is different. Smart offices depend on a denser mix of connected endpoints. A typical floor might include ceiling-mounted wireless access points every few thousand square feet, occupancy and environmental sensors, digital signage, meeting room schedulers, badge readers, surveillance cameras, IP phones, and a growing number of PoE-powered devices. Each one seems small in isolation. Together they create real demands on capacity, power delivery, heat management, and administration. This is where people often underestimate ethernet cabling. They think about speed, but not about everything else riding on the same link. Power over Ethernet changes the conversation. If your switches are powering access points, cameras, and control devices through the cable, the quality of the cabling system matters even more. Cable bundle size, conductor type, termination quality, and pathway management all affect real-world performance. Smart office environments also change quickly. One tenant may begin with standard office use, then shift to hybrid meeting spaces with higher AV and wireless density. Another may deploy sensor-heavy space utilization tools across an entire floor. A structured cabling plan should anticipate that kind of evolution rather than assuming today’s device count is the permanent baseline. The standards matter, but so does judgment on site There is a tendency in some purchasing discussions to reduce cabling to category labels alone. Someone asks, “Should we use CAT6 cabling or CAT6A cabling?” That is a fair question, but it is not the only one that matters. Industry standards exist for good reason. They define performance targets for bandwidth, insertion loss, alien crosstalk, termination practices, and testing. They help ensure interoperability and give owners confidence that the system can support intended applications. But standards do not replace field judgment. Real buildings introduce messy variables: old risers, tight conduits, mixed-use ceilings, shared telecom rooms, electrical interference, and phased occupancy schedules. I have worked in beautifully designed offices where the original plan looked excellent on paper, yet the telecom room ended up undersized once the AV team, security contractor, and IT staff all landed their gear. The issue was not a lack of standards compliance. It was a lack of coordination. Good business network installation requires both technical discipline and practical foresight. The best cabling teams think beyond pass/fail certification. They consider service loops, access to pathways, patch panel growth, proper bend radius, separation from power, heat in closed racks, and whether a maintenance technician can actually identify and replace a run two years later without opening half the ceiling. Choosing between CAT6 cabling and CAT6A cabling For many office projects, the CAT6 versus CAT6A decision sits at the center of planning. Both can support modern business needs, but they serve different priorities. CAT6 cabling remains common because it offers solid performance for many office environments at a lower material and installation cost than CAT6A. For standard workstation drops, VoIP phones, printers, and many general-purpose endpoints, it often makes economic sense. It is also easier to handle in tighter spaces because the cable is usually less bulky and less stiff. CAT6A cabling becomes more attractive when businesses want stronger headroom for 10-gigabit applications over longer distances, better protection against alien crosstalk, or greater long-term flexibility for dense smart office deployments. In practice, CAT6A is frequently specified for newer offices where owners want to avoid opening ceilings again in a few years. It is also a sensible option for high-density wireless environments, advanced AV systems, and spaces expected to add more PoE devices over time. The trade-off is real. CAT6A usually costs more in both materials and labor. The cable diameter can reduce pathway capacity. Terminations require care. If rack and pathway design are sloppy, the extra cable bulk can create its own operational headaches. That does not make CAT6A the wrong choice. It simply means the category decision should be made in the context of the whole system. A practical approach is to match cable type to actual use cases. Some businesses wire all horizontal runs in CAT6A for uniformity and future readiness. Others use CAT6A for wireless access points, conference rooms, backbone-critical drops, and strategic device locations, while using CAT6 cabling elsewhere. The best answer depends on floor layout, expected occupancy, budget, technology roadmap, and how long the business plans to remain in the space. Smart office systems that deserve attention during design Businesses often think first about employee devices, but some of the most important cabling decisions involve infrastructure systems that arrive later in the project. That is where coordination failures show up. Wireless access points are a good example. Coverage plans can change after a predictive survey or post-construction validation. If you do not provide enough cable routes and ceiling access flexibility early, every adjustment becomes more expensive. The same applies to security cameras. Camera counts tend to grow after stakeholders realize what angles they actually need. Conference rooms are another repeat offender. Teams want simple plug-and-play experiences, but the room may require data cabling for a room scheduler, a codec, a control processor, a display, a wireless presentation device, and one or more access points nearby. If the room was originally treated like a basic office with two data jacks, the retrofit gets messy fast. Access control and building automation also deserve closer attention than they usually get. These systems may be installed by different vendors under separate contracts, yet they depend on the same pathways, risers, telecom rooms, and patching discipline. When those vendors are not coordinated under one structured cabling strategy, everyone improvises. Improvisation is expensive in finished office space. What good network cabling installation looks like Quality in network cabling installation is not hard to recognize once you know what to look for. It shows up in planning, craftsmanship, testing, and documentation, not just in the final photo of a tidy rack. A good installer starts by understanding device counts, growth expectations, and technology dependencies. They verify pathway capacity instead of assuming drawings match reality. They coordinate with electrical, HVAC, furniture, security, and AV trades so cable routes stay accessible and compliant. They ask smart questions about where users actually work, not just where desks appear on a plan set. On the installation side, details matter. Cables should be properly supported, not draped across ceiling tiles or tied to anything convenient. Bend radius should be respected. Terminations should be consistent. Patch panels should be clearly labeled. Racks should allow room for cable management and airflow. If PoE loads are significant, cable bundling and switch power planning should be considered up front. Testing is another area where strong contractors separate themselves. Every permanent link should be certified with appropriate test equipment, and results should be turned over in a usable format. If there are failed links, they should be fixed, not explained away. Owners paying for a professional business network installation should expect proof that the system performs as specified. Documentation often gets neglected, even on expensive projects. That is a mistake. Accurate labeling schedules, as-built drawings, and panel maps save enormous time later. I have seen minor office changes turn into disruptive service calls simply because nobody could confirm which patch panel ports served which conference rooms. Common mistakes that create expensive problems later Most structured cabling problems are preventable. They come from rushing design, buying on lowest price alone, or treating the cabling contractor as an afterthought. Here are the issues I see most often: Underestimating future device growth, especially for wireless, cameras, sensors, and room technology Installing too few pathways or leaving telecom rooms without enough rack and power capacity Choosing cable category based only on upfront cost, without considering lifecycle use Skipping rigorous labeling, testing, and as-built documentation Letting multiple low voltage vendors run cabling independently, without a unified plan Each of these looks manageable during construction. Each becomes more painful once the office is occupied. Opening finished walls to add data cabling is far more expensive than installing spare capacity during the build. The same goes for adding pathway space or reworking overcrowded closets after the fact. Budgeting with the long view Cabling budgets are often judged too narrowly. Decision-makers compare bid totals and assume the lowest number creates savings. That may be true only if the office remains static and if everything is installed correctly the first time. Those are risky assumptions. A better way to think about cost is over the life of the space. Structured cabling may stay in place for ten years or longer, even as switches, access points, and endpoints are refreshed several times. If a slightly higher investment now prevents repeated change orders, supports better wireless performance, and reduces downtime later, it often pays for itself quietly. There is also a labor reality many owners overlook. The difference in material cost between cable categories or between average and better-quality components may not be the largest part of the budget. Labor, access conditions, schedule compression, and retrofit complexity can drive substantial cost. Once walls are closed and furniture is installed, every additional cable run becomes harder. That is why good planning usually saves more money than aggressive value engineering. Value engineering has its place, but removing backbone capacity, cutting spare drops, or shrinking telecom room allowances often creates false economies. Retrofitting an existing office without making a mess Not every smart office starts in a shell space. Many businesses need to modernize an occupied office with older network cabling already in place. That work is more delicate, but it can be done well. The first step is to verify what you actually have. Not what an old drawing says, and not what someone remembers from a move five years ago. You need a site assessment. That includes identifying existing cable types, pathway conditions, rack capacity, labeling quality, switch power availability, and device locations. In older offices, surprises are common. Unused cable is left in place. Patching may be inconsistent. Legacy phone cabling may occupy routes you need for current systems. After that, phasing becomes critical. If the office is occupied, you may need after-hours cutovers, temporary wireless support, or staged room-by-room migration. A clean retrofit depends on sequencing as much as on technical skill. Businesses sometimes assume retrofitting data cabling is a minor trade. In practice, a poorly planned upgrade can disrupt operations quickly. A smart retrofit also involves selective reuse. Not every existing run needs replacement. Some can remain if they meet current needs and test properly. Others may serve low-demand endpoints while new CAT6A cabling is added for access points, conference spaces, or strategic future growth. Good design is not about replacing everything. It is about aligning the physical network with actual business requirements. Questions to ask before signing off on a cabling plan Business owners, facilities leaders, and IT teams do not need to become cabling experts, but they should ask a few hard questions before approving a project. How many additional connected devices could this floor support without major recabling? Which runs are intended for high-bandwidth or high-PoE applications, and why? Do the telecom rooms have enough space, power, cooling, and rack capacity for growth? Will the installer provide certification results, labels, and accurate as-built documentation? If we reconfigure departments or conference rooms in two years, how easily can this system adapt? Those questions often reveal whether a proposal was designed thoughtfully or priced quickly. If the answers are vague, the office is probably heading toward avoidable change orders later. The real value of doing it right Structured cabling is one of those investments that rarely gets applause when completed well. It sits in the background, quietly enabling the visible parts of a smart office to do their job. That can make it tempting to trim. In my experience, businesses regret weak cabling infrastructure far more often than they regret building in sensible capacity. Reliable office network cabling supports productivity in ordinary moments, not just during outages. It shortens onboarding time when teams grow. It makes conference rooms work consistently. It helps Wi-Fi perform the way the design promised. It simplifies moves, adds, and changes. It gives security and facilities systems a stable foundation. It reduces the number of mysterious technology issues that turn into finger-pointing between vendors. The offices that age best are usually not the ones with the flashiest launch. They are the ones with disciplined infrastructure choices underneath. If a business is serious about creating a smart, adaptable workplace, structured cabling should be treated like a core asset. Not because cable itself is exciting, but because every connected system depends on it.

Read more about Structured Cabling for Smart Offices: What Businesses Need to Know